Free Member 
Language :
CV. ANDALAN PRIMA SEJAHTERA
CV. ANDALAN PRIMA SEJAHTERA
http://indomonster.com/cv_aps/
CV. ANDALAN PRIMA SEJAHTERA
Contact Information
Name:
Mrs. REGINA / VANNY / VITHA [Director/CEO/General Manager]
E-mail:
Homepage:
Instant Messaging:
Y!: andalan1974@yahoo.com 
Phone Number:
Phone number of Mrs. REGINA / VANNY / VITHA at JAKARTA
Mobile Number:
Mobile number of Mrs. REGINA / VANNY / VITHA at JAKARTA
Fax Number:
Fax number of Mrs. REGINA / VANNY / VITHA at JAKARTA
Address:
Jl. muchtar tabrani, Perum Bintang Metropol Blok A7/16 Bekasi
JAKARTA, Jakarta
Indonesia
Average User Review

There is no review for this company

Write a review

Products Catalog

HIOKI 3805-50 DIGITAL HiTESTER
Quantity Order:
Payment MethodTelegraphic Transfer (T/T)
Pack. & Delivery1 unit
OriginJapan

Specification

Demonstrate the Power of your DMM during Facilities Maintenance :

- For Instrumentation (4 - 20mA% display)
- For Power line distortion check (Harmonic distortion % display)
- True RMS rectification of your harmonic-ridden signal, Basic accuracy ±0.09%
- For cooling equipment maintenance (Simultaneous 2-point temperature measurement)
- New ! Temperature scanning function (T1, T2, T1 - T2)
- New ! PC communication via USB or RS-232C (using optional accessories)

Basic specifications :

DC Voltage : 999.9mV to 999.9V, 4 ranges (Basic accuracy: ±0.09% rdg. ±2dgt.)
AC Voltage
40 to 2kHz : 999.9mV to 999.9V, 4 ranges
(Basic accuracy: ±1% rdg. ±5dgt. /true RMS rectified, crest factor 3 or less)
Resistance : 999.9& to 99.99M&, 6 ranges (Basic accuracy: ±0.3% rdg. ±3dgt.)
DC Current : 999.9¼A to 9.99A, 5 ranges (Basic accuracy: ±0.1% rdg. ±3dgt.)
AC Current
40 to 2kHz : 999.9¼A to 9.99A, 5 ranges (Basic accuracy: ±1% rdg. ±5dgt. /true RMS rectified, crest factor 3 or less)
Hz
(Frequency) : 9.999Hz to 999.9kHz
(Accuracy: ±0.03% rdg. ±3dgt./Input level: 0.5V to 1000V, minimum frequency 0.5Hz)
Temperature
(Thermocouple) : [K] -40°C to 1372°C, [J] -40°C to 1200°C
(Basic accuracy: ±0.3% rdg. ±3°C/add to the accuracy of the temperature probe)
Contact check : Buzzer sounds at a resistance equivalent to or less than 100 counts for each range
Diode check : Open-terminal voltage: less than 3.5V, Measurement current 0.46mA
Capacitance : 9.999¼F (resolution 1nF) to 9.999mF (resolution 1¼F), 4 ranges (Basic accuracy: ±2% rdg. ±5dgt.)
Other functions : Recording value of maximum, minimum, averaging, Trigger-hold, Refresh-hold, Harmonic %, 4-20mA % , Relative value, Auto-power save, RS-232C/USB communication
Display : Digital LCD, max. 9999 digit
Sampling rate : 7 times/s, 4 times/s (at capacitance measurement up to 100 ¼F), 1 time/s (at frequency measurement range)
Power consumption : 6F22 (Stacked manganese battery) × 1, Continuous use: 30 hr
6LR61 (Stacked alkaline battery) × 1, Continuous use: 60 hr
Dimensions, mass : 83mm (3.27 in) W × 178mm (7.01 in) H × 58mm (2.28 in) D, 400g (14.1 oz) (with holster and battery)
Supplied accessories : Test Lead 3851-10 × 1, Holster × 1, Battery (6LR61) × 1 (for trial purposes only)