Welcome to
SOLARIS-NEWTECH, INC.

Free Member
SOLARIS-NEWTECH, INC.
China
  • Sell

    NT3 Series Multiparameter Patient Monitor with various screen sizes--12.1''£¬10.4'', 8.4'', 6.4''

    NT3 Series Multiparameter Patient Monitor with various screen sizes--12.1''£¬10.4'', 8.4'', 6.4''

    Quantity Order:
    Payment Method:
    Telegraphic Transfer (T/T)
    Quantity:
    min 1 pc
    Pack. & Delivery:
    standard
    12.1''£¬10.4'',8.4'',6.4''sceen sizes available, take NT3B for example:

    NT3B: Multiparameter Monitors 12.1" Display

    12.1" High Brightness TFT LCD
    1-8 Channel Waveform Display
    7 Channel ECG Waveform Display; ST Segment
    Analysis; Arrhythmia Analysis
    Anti-movement and low perfusion SpO2 Measurement
    Pace Pulse Detection
    Defibrillation and ESU Protection
    OxyCRG diagram; Drug Dose Calculation
    Blood Dynamics Ananlysis
    Venous Punch
    Flexible Parameter Configuration

    Product Features :

    ECG
    ECG Cable: 5 Leadwires ECG cable
    Lead section:
    lead I, II, III/aVR, aVL, aVF/ V
    Gain£¨mm/mV£©: 1/4£¬1/2£¬1£¬2£¬4
    Frequency response:
    Diagnosis: 0.05 - 100Hz
    Monitor: 0.5~40 Hz
    Surgery:1.0~25 Hz
    Sweep speed(mm/sec):6.25,12.5, 25, 50
    Heart rate range: 30-300 BPM
    Heart rate accuracy : ¡À 1 %
    ST segment deviation analysis:
    -0.8~+0.8mV
    ST accuracy : ¡À0.02mv

    Non-Invasive Blood Pressure
    Measurement type :
    adult, pediatric, neonatal
    Measurement range:
    Systolic¡¡ 4.0 - 270mmHg
    Diastolic ¡¡20 - 200mmHg
    Mean 30 - 220mmHg
    Accuracy : ¡À3mmHg or 2 %(choice max)
    Resolution:1mmHg
    Protection: over pressure

    Pules Oximetry
    SPO2 measurement range: 0 - 100 %
    Accuracy: ¡À2% at 70~100%
    (no specification under 70%)
    Resolution: 1 %
    pulse measurement range:30- 250BPM
    Accuracy: ¡À2 % or 1BPM (choice max)
    Resolution: 1 BPM

    Respiration Rate
    Measurement range: 0 - 120 BPM
    Accuracy: ¡À1 BPM or 5 %(choice max)
    Resolution: 1 BPM

    CO2
    Measurement range:
    0 % - 10.0 % £¨in CO2 and et CO2£©
    Accuracy:
    ¡À 2 mm Hg£¨5 % Measurement value£©
    Response time: 180 ms

    IBP
    Channel number: 2ch
    range: -40 - +330mmHg
    Accuracy: ¡À4mmHg or ¡À4%(choice max)
    Resolution: 1mmHg

    Environment
    Opreation Storage
    Temperature: 5~40 ¡æ -20~70 ¡æ
    Relative humidity: ¡Ü 80% ¡Ü 95%

    Temperature
    Channel number: 2ch
    Measurement range: 25~45 ¡æ
    Accuracy: ¡À0.1 ¡æ
    Resolution: 0.1 ¡æ
    response time: ¡Ü 3 min

    Power Requirements
    Input: 98-260 V AC, 50/60Hz
    Consumption: ¡Ü 80VA